widely used airtraq optical laryngoscope in pakistan

widely used airtraq optical laryngoscope in pakistan

price:face to face

IN STOCK1000

Airtraq - an overview | ScienceDirect Topics 4. The Airtraq optical laryngoscope (AOL; Prodol, Vizcaya, Spain) is a single-use indirect laryngoscope for tracheal intubation ( Figure 5 ). The AOL comes in two pediatric sizes: infant (size 0)

other product

Airtraq - an overview | ScienceDirect Topics

Airtraq - an overview | ScienceDirect Topics

4. The Airtraq optical laryngoscope (AOL; Prodol, Vizcaya, Spain) is a single-use indirect laryngoscope for tracheal intubation ( Figure 5 ). The AOL comes in two pediatric sizes: infant (size 0) for ETT 2.5–3.5 and pediatric (size 1) for ETT sizes 3.5–5.5. Both sizes require a mouth opening of 12–13 mm.

Use of Airtraq® optical laryngoscope for the intubation in

Use of Airtraq® optical laryngoscope for the intubation in

Equipment for direct laryngoscopy, size 2, 3 and 4 of Airtraq ® optical laryngoscope and ultra-thin flexible fibreoptic bronchoscope (2.0 mm size) were kept ready. Intravenous line was secured in the ward and no sedation was administered. Inside the operation theatre, she was administered glycopyrrolate 0.2 mg plus midazolam 1 mg.

The use of the Airtraq® optical laryngoscope for routine

The use of the Airtraq® optical laryngoscope for routine

The Airtraq ® optical laryngoscope (Prodol S.A., Vizcaya, Spain) is a single-use rigid video laryngoscope that has been developed to facilitate tracheal intubation in both, patients with normal or difficult to intubate airways [11, 12, 13]. The resulting glottic view is provided without an alignment of the oral, pharyngeal and tracheal axes.

Airtraq™ versus Macintoch laryngoscope in intubation

Airtraq™ versus Macintoch laryngoscope in intubation

Airtraq™ is an optical laryngoscope that allows viewing of the vocal cords without a direct line of sight. The main objective of this prospective, randomized, controlled trial was to evaluate Airtraq intubation characteristics, mainly intubation time and cardiovascular changes in the pediatric patients.

AIRTRAQ® OPTICAL LARYNGOSCOPE FOR TRACHEAL

AIRTRAQ® OPTICAL LARYNGOSCOPE FOR TRACHEAL

The Airtraq® optical laryngoscope (AL) (Prodol Ltd. Vizcaya, Spain) is a relatively new . with the latter to be used most commonly like in our case7,18. The operation site was at the same level and in close proximity with the airway while the patients’ head was covered. For these reasons, someone

(PDF) Airtraq ® versus Macintosh laryngoscope: A

(PDF) Airtraq ® versus Macintosh laryngoscope: A

Results: We observed that Airtraq was better than the Macintosh laryngoscope as duration of successful intubation was shorter in Airtraq 18.15 seconds (±2.74) and in the Macintosh laryngoscope it .

(PDF) The use of the Airtraq(R) optical laryngoscope for

(PDF) The use of the Airtraq(R) optical laryngoscope for

ABSTRACT: The Airtraq® optical laryngoscope (Prodol Ltd., Vizcaya, Spain) is a novel disposable device facilitating tracheal intubation in routine and difficult airway patients.

AIRTRAQ OPTICAL LARYNGOSCOPE: ADVANTAGES AND

AIRTRAQ OPTICAL LARYNGOSCOPE: ADVANTAGES AND

However Airtraq laryngoscope is a novel intubation device which has been introduced to the clinical practice in recent years during the videolaryngoscopic revolution and its utilization is rapidly becoming more and more widespread. Airtraq was previously used in normal and difficult airways to compare with both Macintosh laryngoscope and other

Use of Airtraq® optical laryngoscope for the intubation in

Use of Airtraq® optical laryngoscope for the intubation in

Equipment for direct laryngoscopy, size 2, 3 and 4 of Airtraq ® optical laryngoscope and ultra-thin flexible fibreoptic bronchoscope (2.0 mm size) were kept ready. Intravenous line was secured in the ward and no sedation was administered. Inside the operation theatre, she was administered glycopyrrolate 0.2 mg plus midazolam 1 mg.

The use of the Airtraq® optical laryngoscope for routine

The use of the Airtraq® optical laryngoscope for routine

The Airtraq ® optical laryngoscope (Prodol S.A., Vizcaya, Spain) is a single-use rigid video laryngoscope that has been developed to facilitate tracheal intubation in both, patients with normal or difficult to intubate airways [11, 12, 13]. The resulting glottic view is provided without an alignment of the oral, pharyngeal and tracheal axes.

The Airtraq Optical Laryngoscope in Helicopter Emergency

The Airtraq Optical Laryngoscope in Helicopter Emergency

 · The Airtraq (AT) optical laryngoscope (Prodol Meditec, SA, Bizakia, Spain) was designed to improve success in endotracheal tube placement in difficult airway scenarios. The device allows for indirect visualization (ie, “targeting”) of the vocal cords and airway anatomy through a series of mirrors and light-emitting diode lighting.

Airtraq | Guided video intubation

Airtraq | Guided video intubation

Airtraq’s channel simplifies ETT insertion reducing intubation time. No stylet needed. Avoids potential injuries. Eliminates stylet costs. 90º shape minimizes hyperextension and reduces force required. Reduces hemodynamic reactivity; Facilitates intubation from any position (face to face, etc.). High intubation success rate in Difficult Airways.

A comparative evaluation of the Airtraq and King Vision

A comparative evaluation of the Airtraq and King Vision

The time required to intubate patients was significantly shorter when the King Vision video laryngoscope with channeled blade was used as compared to the Airtraq (p < 0.05). The number of attempts to successfully intubate patients was also significantly lower (p < 0.05) for the King Vision video laryngoscope than for the Airtraq.

A comparison of exposure of Glottis using the Airtraq or

A comparison of exposure of Glottis using the Airtraq or

 · Airtraq is one of the relatively inexpensive and widely used video-laryngoscopes in China.6,18 Airtraq adopted in the experiment attributed to less haemodynamic stimulation following tracheal intubation in comparison with Macintosh laryngoscope.7,19,20 This finding probably reflects the fact that Airtraq provides a view of glottis without the .

A comparison of cervical spine movement during

A comparison of cervical spine movement during

The Airtraq ® laryngoscope has an oropharyngeal airway‐shaped blade that provides a non‐line‐of‐sight view of the glottis. The configuration of the blade should mean that less movement of the cervical spine is required during laryngeal visualisation. We compared the degree of cervical spine movement in laryngoscopy performed using the Airtraq and conventional Macintosh laryngoscope.

Use of airtraq optical laryngoscope for naso tracheal

Use of airtraq optical laryngoscope for naso tracheal

64 Case report Use of Airtraq optical laryngoscope for Naso-tracheal intubation in Anaesthetized patients. Sunny Malik1 ,Shahin N Jamil2 ,Shraddha Malik3 ,Rohi…

Original Article A comparative study of tracheal

Original Article A comparative study of tracheal

Macintosh and Airtraq laryngoscope Samal 2RK1, Kundu R , Ghosh M3, Singha S4 ABSTRACT Background: Direct laryngoscopy for endotracheal intubation with the Macintosh blade is most commonly used for establishing a patent airway. AirtraqTm Optical Laryngoscope, does not require the alignment of the 3 airway

Airtraq® versus Macintosh laryngoscope: A comparative

Airtraq® versus Macintosh laryngoscope: A comparative

Background: The curved laryngoscope blade described by Macintosh in 1943 remains the most widely used device to facilitate tracheal intubation. The Airtraq ® (Prodol Meditec S.A, Vizcaya, Spain) is a new, single use, indirect laryngoscope introduced into clinical practice in 2005. It has wan exaggerated blade curvature with internal arrangement of optical lenses and a mechanism to prevent .

Airway management with simultaneous cervical spine

Airway management with simultaneous cervical spine

 · Results. The mean time required to obtain the laryngeal inlet view and the mean intubation-to-successful-ventilation time were significantly shorter when the Airtraq ® device was used, 5.5 s (±1.5) and 9.8 s (±2.7) respectively (p = 0.003 and 0.0006). There were no failed intubation attempts in the Airtraq ® group and the use of this device had the lowest incidence of incisors damage (2 in .

Original Research Paper Volume-9 | Issue-6 | June-2019

Original Research Paper Volume-9 | Issue-6 | June-2019

The Macintosh laryngoscope is the most commonly used device for pediatricorotracheal intubation. Airtraq is an optical laryngoscope which has a guiding channel in which to place the tracheal tube and a heating system to prevent fogging of the view finder. We compared Airtraq with the Macintosh laryngoscope and assessed the ease of

Research Article Airway Management with Cervical Spine

Research Article Airway Management with Cervical Spine

Evo laryngoscopes (.s and . s, resp.) but signi cantly prolonged for the Totaltrack VLM device (.s). ese results are comparable with those achieved in similar studies in a group of patients anaesthetised for elective procedures [ ]. In a study by Maharaj et al. the Airtraq® optical laryngoscope was shown to reduce intubation time when